Empirum Service Bus Publishing Options
Control What Is Published (Empirum Options)
An Empirum Option (EmpOption) for published objects can contain the following values:
EmpValue | Description |
0 | Do not publish objects of the related type. |
1 | Execute initial publishing of all objects of the related type. |
2 | Publish single objects of the related type if they change. |
Empirum DB table Options contains the following feature toggles (Empirum Options) for several Empirum objects that are published.
Usually, the value will be set to '2' after the first installation and already processed initial syncs (publishing of all objects of a kind).
It is possible to set the value back to '0' to shut off the publishing completely or to set the value to '1' to initiate a complete RE-publish of all the objects of a kind.
The initial sync (publishing of all objects) is available for most types of objects.
The available options depend on the installed Empirum version.
EmpOption | Initial Sync Support | Related Empirum Object |
UemDeviceSyncActivated | Yes | Client computer |
UemInventorySoftwareSyncActivated (set to '0' by default as not all license management processes are supported yet - do not enable this value for now as it will lead to duplicate fingerprints) |
Yes: only Initial Sync | Installed applications (Inventory) found on a managed client |
UemBootImageSyncActivated | Yes | Boot configuration for OS deployment |
UemPmStatusSyncActivated | No | Patch Management status |
UemPatchManagementGroupSyncActivated | Yes | Patch Management group |
UemSoftwarePackageSyncActivated | Yes |
Any Empirum (software) package: UEM Agent Template, Software Application, OS Install Image, OS Language Pack. Trigger a full sync publishes all listed objects. Re-import the OS Install Images from the disk using EMC will find all OS (Install) Images (metadata) and publishes then on the Service Bus. |
UemStatusSyncActivated | No (But could be done indirectly using 'UemSoftwareInstallationStatusLastRun' option described below) |
UEM Agent status / Last software installation status |
UEMBootImageSyncActivated | Yes | Boot Configurations |
UEMAgentTemplateSyncActivated | Yes | Agent Template Configurations |
UEMHardwareDriverSyncActivated | Yes | Hardware Drivers for WinPE based OS deployments |
UEMVariableConfigurationSyncActivated | Yes | Variable Configurations |
Additionally, there are Empirum options that have different values but are also used to control publishing.
EmpOption | EmpValue | Description |
UemSoftwareInstallationStatusLastRun | Last processed ID from table ArchiveDistJobs | Software package installation status Or UEM Agent status. This Empirum Option is directly related to the 'UemStatusSyncActivated' option described upon. All software depot logs are stored in that table and the ID of the last processed record is stored in UemSoftwareInstallationStatusLastRun. It is possible to RE-publish all the history by setting the value to '0'. Be aware there could be tens of thousands of records in that table. |
Changes can only be done exclusively directly on the DB.
Additional settings:
EmpOption | EmpValue | Description |
UemServiceBusDisplayName | Name to be shown in node information on DWP | Sets the name string which is send as request to the heartbeat message from the DWP. |